Welcome to our Mining equipment manufacturing base, Contact Us


Get More Information

Hermetic seal - Wikipedia

Epoxy hermetic seal designs can be used in hermetic seal applications for low or high vacuum or pressures, effectively sealing gases or fluids including helium gas to very low helium gas leak rates similar to glass or ceramic.


The most current model, the Seal Integrity Monitoring System (SIMS) 1915+, is the ideal choice for your helium-based leak detection system. Compared to conventional vacuum bubble and dye penetration test methods, packages can be quantitatively tested using helium as the tracer gas that ensures higher levels of accuracy.


Technology Introduction USP <1207> | Helium Leak Testing (Mass Spectrometry) In a retrospective published in 1991, Albert Nerken traces the origins of helium leak detection to development of the Uranium 235 bomb via the Manhattan Project. The process and equipment designed to isolate this U (235) isotope required the absolute absence of ambient ...


as rubber hoses, elastomer seals, etc. (unless these parts have become brittle and thus "leaky"). 5 aetas of ea etecto 2 Leak rate, leak size ... is recommended to use a helium leak detector with which the leaks may also be localized significantly faster. Fundamentals of Leak Detection


flanges for both types of seals have a leak test port that has been proved to be blockage free. The allowable leakage rate for the Raco/Creavey seals is 0.183 SCIM of helium at 50 ± 5.0 PSIG and ambient temperature. The propulsion line mechanical joints are leak checked in final


RHSeals can seal stranded wire as well as it seals solid conductor or solid pins. Most RHSeals hermetic seals will pass a helium leak rate of 1X10-8 std-cc/sec or better, and pressure tests up to 11,000 psi (758 bar). Please see the drawing for the individual part number you are interested in to verify the test specifications and operating limits.


Here, we list some topics related to actual sealing methods and sealing technology.1.Sealing gaskets. Gasket seals. O-ring seals. Recommended design for O-ring grooves. Sealing WORKs with large openings. 2. Clamp mechanisms. Tooling stoppers. Calculating clamping force.


For a seal with a nominal diameter of DN 500 ISO-K, the permeation of atmospheric air with 60 % humidity is approximately 4 · 10-7 Pa · m 3 /s. In vacuum systems with FKM seals, an operating pressure greater than 1 · 10-8 hPa is therefore rarely achieved. Elastomer seals can be reused several times, if properly used.


Typical Helium Leak Rate ( per mm circumference) Equivalent leak rates for other gases: Multiply the helium leakage rate by the following factors to obtain the leakage rate of the following gases. Oxygen: 0.35 Nitrogen: 0.37 Hydrogen: 1.42 Air: 0.37 Seal Type E …


Fine leak tests are commonly performed by measuring the rate at which the seal leaks helium. This method uses a mass spectrometer that is calibrated for helium. The hermetic seal to be tested is placed in a port on the helium test equipment …


Call: 708-425-9080. C-ring Seals – A Versatile Solution for Extreme Sealing Environments. This is a technical information article only. Meyer Tool manufactures custom pressure, vacuum and cryogenic systems. We use c-rings for certain applications. Meyer Tool does not manufacture or distribute C-rings. A critical element in designing any ...


For testing hermetic package leak rates, MicroCircuit Laboratories ( MCL) required test capability to detect both gross and ultra-fine leak rates. Gross leak testing was of considerable importance because a gross leak failure, by letting all the helium escape the package, can result in …


High Sensitivity Helium Leak Detection (HSHLD ®) was developed by ORS to simultaneously measure Helium and Oxygen to determine Fine and Gross leaks in one simplified test.The HSHLD ® method is a dry method that is sensitive to 10-12 atm cc/sec with cycle times less than 2 minutes and can measure devices with internal free volumes as small as 0.005cc.


Jan 01, 2000· In most early electronic systems, hermeticity was achieved by using a metal enclosure and glass-to-metal seals with a leak rate of less than 10-8 He/cm 3 /sec of He at STP. It was thought that, at this low level of leakage of a small atom such as helium, the exclusion of moisture and its corrosive effects would be assured.


The Metal Seal Gasket Replacement Kit it is specially designed for VS Series Helium Mass Spectrometer Leak Detectors. This kit includes the metal gaskets only. (This kit does NOT include the ion supports or the filaments).


Nov 01, 1991· Leak rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10-9 std cm3 s 1, during testing. Keywords: helium; leaks; seals In the past, Wood's metal, copper, aluminium, tin and indium have been used to make demountable seals for cryogenic applications.


Custom Seal. 2.651in. x 2.651 in x .156 in. wall thickness x .50 thick All of our urethane seals are now available in three grades: 1) Standard - general purpose 2) Premium - 50% greater wear life 3) Medical - FDA approved material.


ISO 9001 quality system. Also, many of our hermetic seal wire or pin connectors are able to be rated and tested to much higher pressures or significantly lower vacuum helium leak rates as low as 4 x 10^-10 cc/sec if an o-ring face seal type design, than what may be shown on the drawings. Copper alloy wires or pins are sealed for the best ampacity.


4, 1/ tracer gas helium (He) fine leak. Apparatus required shall consist of suitable pressure and vacuum chambers and a mass spectrometer-type leak detector preset and properly calibrated for a helium leak rate sensitivity sufficient to read measured helium leak rates of 10-9 atm cc/s and greater. The volume of the chamber


Helium Leak Testing. The most sensitive seal integrity testing technique is the use of helium leak detection. This technique offers advantages over other conventional seal integrity test methods. West uses a Seal Integrity Monitoring System (SIMS™) for helium leak detection. The system is based on a helium mass spectrometer leak detector ...


The resultant UHV seal has a helium leak rate of of less than 1 X 10 -11 standard cc/sec. They can also be baked repeatedly to 150°C (302°F). The EVAC chain clamp and an aluminum knife edge seal form the UHV vacuum seal between the connecting KF flanges. (please see far right graphic above - click to enlarge).


A commonly observed example of permeation occurs during long-term helium probing or bagging during leak detection where the leak detector's helium signal slowly increases due to helium permeation instead of the sharp signal increase expected from a real leak. Most O-ring materials are more permeable to helium than they are to air.


If helium is detected which exceeds the preset leak rate set point, an alarm alerts the operator of a fine leak failure. GROSS LEAK SEAL TESTING- HERE'S HOW IT WORKS Gross Leak Testing is accomplished by a two-part process:


2 Filament Installation: Agilent Helium Leak Detector Model G8610, G8611, or G8612 The same filament replacement kit is compatible with any model G8610, G8611, or G8612, as


Helium leak testing HLT is performed by placing units to be tested in a chamber and then pressurizing that container with Helium. Pressures of 90 to 120 PSI are typical of the exposure for standard leak tests. Wilcoxon uses 120 PSI. After an appropriate time of exposure, the units are removed and, one at a time, placed in a test chamber.


Jun 12, 2013· Using the INFICON UL1000 helium leak detector and the test chamber TC1000, it is very easy to perform a fast and reliable hermetic seal test with previously ...


Helium Fine Leak Hermeticity Testing. Helium hermeticity testing is used to verify the seal process of a hermetic device. Devices are typically preconditioned in a pressurized chamber and, after the required conditions are met, the leak rate is measured and recorded, applying pass/fail criteria. ORS holds DLA Laboratory suitability in the seal ...


The Seal Integrity Monitoring System (SIMS) Model 1915+ is a helium-based leak testing system that features an oil-free pump, detector and integrated power system. It enables quantitative analysis of package systems at sensitivity levels as low as 1 x 10 -10 cc/s at room temperature.


Jan 31, 2006· RE: Sealing helium gas in medical devices RichardMc (Industrial) 31 Jan 06 13:25 Information about seals for medical applications can be found at class-vi-o-rings.com.


Jan 01, 2011· Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two …


The Ferrofluid Rotary Vacuum Seal provides a hermetic atmospheric to high vacuum rotary vacuum seal under both static and dynamic conditions; providing protection from gas, vapor and other contaminants. The Leakage rate specification is 1 x 10‐9 std. cc/sec. All ferrofluid rotary vacuum seals are helium leak checked with a helium mass ...


Jul 20, 2017· While the small size of helium benefits servo writing, it is extremely difficult to seal the helium within the drive. Anyone who has purchased a helium filled balloon knows that after a few days, the helium leaks out. Investing over 15 years of R&D, HGST solved the sealing challenge and launched our first high volume 6TB HDD (Ultrastar He6 ...